Anesthesia Bain Circuit – INTERSURGICAL
Ayres T-Piece Bain Circuit – INTERSURGICALS
Capnograph – Handheld
Introduction
The device adopts side-stream method to measure the parameter related to ETCO2 and AWRR. It can detect pulmonary ventilation function and reflect the circulation and pulmonary blood flow and indirectly reflect the alveolar ventilation. It can also detect the blood oxygen saturation and pulse.
- End-tidal CO2 measurement function;
- Respiration rate measurement function;
- SpO2 measurement function;
- Pulse rate measurement function;
- Optional three units;
- With audible and visual alarm and silencing functions, the alarm limit can be set;
- Over-limit alarm function for EtCO2, Respiration rate, SpO2 and Pulse rate;
- Low battery alarm function;
- With the prompt function of “Checking Filterline”;
- User can calibrate zero by themselves.
- With atmospheric pressure and temperature compensation functions
- Rechargeable lithium battery, up to 8-hour user time;
CBI Portable Infusion Bottle
CBI Ambulatory Elastomeric Infusion Pump is a one-time-use, portable elastomeric infusion pump that promises medicine at a constant, pre-determined flow rate.
- Comfortable & Safe for patients.
- Volume: 250ml
- Stable flow rate of 5ml/Hour for error free therapy.
- Ambulatory & portable design, therapy not limited by body position and space.
- Doesn’t require continuous patient monitoring.
- In PCA pumps patient self-control the additional dose and according to their pain situation.
- No battery or power supply required, allows patients to move.
- Used for multiple therapies.
- Avoids the risk of Air embolism
- DEHP-free & Latex-free
- Disposable and Safe.
- Closed mechanism for less contamination.
- Available in multiple specifications suitable for all clinical requirements.
- Bags can be purchased with the pump to carry the pumps.
- High drug compatibility with NewFuser®
Endotracheal Tubes
Infant High Intensity LED Phototherapy Lamp – BL – 200D
Contact us for Quote
- Double side phototherapy for more effective radiation: Upside phototherapy and downside
- Three levels to adjust the irradiation: Low, Medium, High
- Upside phototherapy unit adopts big blue LED bulbs, uniform, efficient and long life
- Infant phototherapy unit, equipped with infant bed, convenient for clinical use
- Light head of upside phototherapy unit can be adjusted 360° horizontally and 180°vertically
- With drawers and lockable castors.
Infant Radiant Warmer BN-100A
Infusion Pump – Hawkmed
Contact us for quote
- Compact and light-weight
- Soft-keys for easy operation
- Panel lock feature prevents unauthorised changes to settings
- Last infusion rate and volume limit stored
- Top-mounted light indicates infusion status and alarm condition
- Large colour display with night mode
- Adjustable beeper volume
- Free-flow protection
- At least 3 hours battery life at 25mL/h
- Stores 1500 event logs and alarm information
- Real-time display
- Adjustable alarm volume
- Adjustable occlusion pressure settings
- Air bubble detection alarm
- Removable pump body for convenient cleaning
- Use on desk top or easily mountable on vertical IV pole or horizontal bar using rotatable pole clam
Neonatal Incubator BB-100 – Dison
ONEpro Mesh-nebulizer-CA_MI
Oropharyngeal Guedel Airways
Oxygen Concentrator 3Litres – Contec
- Maximum flowrate recommended: 3L/min
- Flowrate change at maximum recommended flowrate with 5 kPa back pressure: <0.3L/min.
- Outlet pressure: 20kPa~50kPa
- Input Power Consumption: 400VA
- Operating noise: ≤55dB(A)
- SpO2 Measurement Range: 0%~100% Accuracy: ±2% when SpO2 is in range of 70%~100%; unspecified when less than 70% .
- Pulse rate Measurement Range: 30bpm~250bpm Accuracy: ±2bpm or ±2%, whichever is greater